RPS-HR

High Power Battery Pack Tester :

Up to 1000V, Up to 1000A, Max. 500kW

Maker

BaSyTec (Germany)

Features

• 배터리 팩 테스트 시스템

• 최대 1,000A, 1,000V, 500kW

• BSD 시스템 통합

Applications

• 2nd battery

Specifications

Power
Up to 500kW
(1.5MW in parallel
operation)
Voltage range
Up to 1000V
Voltage accuracy /
resolution
0.02% / 24Bit
4-wire measurement
Yes
Current range
Up to 1000A (3000A in
parallel operation)
Current accuracy /
resolution / ripple
0.05% FS / 24Bit / < 0.3% FS
Time resolution
1µs / < 1ms
Current rise time
< 1ms (600V / 800V),
< 2ms (other voltages)
Parallel operation
Yes, up to 3 channels
Current ranges
Optional, up to 2,
automatic ranges switching
Sampling rate
Output change rate
Min. 1ms
but not more than
1kHz continually per system
Standard inputs
Voltage, current,
4 Pt100/4W
Control modes
Current, voltage, power,
resistance and
combinations
Cooling
Air cooled
Power supply
400V / 3 phases, N, GND,
power factor > 0.99
Efficiency
Up to 95%
Noise
Max. 79dB (A)
Isolation monitor
Yes, switchable
Battery simulator mode
Optional but with reduced
accuracy and resolution
and not supported
by the BaSyTest software.
Control via CAN instead. 
Emergency stop
Performance level d
Other options
CAN interface
CMU cell voltage inputs
CMU temperature inputs
SSMS interface
Digital-IO or relay outputs
Software
BaSyTest
Interface
Ethernet

RPS-HR


High Power Battery Pack Tester : Up to 1000V, Up to 1000A, Max. 500kW

Maker:

BaSyTec (Germany)

FEATURES


• 배터리 팩 테스트 시스템

• 최대 1,000A, 1,000V, 500kW

• BSD 시스템 통합


APPLICATIONS


• 2nd battery

SPECIFICATIONS


PowerUp to 500kW (1.5MW in parallel operation)
Voltage rangeUp to 1000V
Voltage accuracy / resolution0.02% / 24Bit
4-wire measurementYest
Current rangeUp to 1000A (3000A in parallel operation)
Current accuracy / resolution / ripple0.05% FS / 24Bit / < 0.3% FS
Time resolution1µs / < 1ms
Current rise time< 1ms (600V / 800V), < 2ms (other voltages)
Parallel operationYes, up to 3 channels
Current rangesOptional, up to 2, automatic ranges switching
Sampling rate
Output change rate
Min. 1ms        but not more than 1kHz continually per system
Standard inputsVoltage, current, 4 Pt100/4W
Control modesCurrent, voltage, power, resistance and combinations
CoolingAir cooled
Power supply400V / 3 phases, N, GND, power factor > 0.99
EfficiencyUp to 95%
NoiseMax. 79dB (A)
Isolation monitorYes, switchable
Battery simulator modeOptional but with reduced accuracy and resolution and not supported by the BaSyTest software. Control via CAN instead.
Emergency stopPerformance level d
Other optionsCAN interface
CMU cell voltage inputs
CMU temperature inputs
SSMS interface
Digital-IO or relay outputs
SoftwareBaSyTest
InterfaceEthernet