FEATURES


  • Voltage : 0 to 6 V(CTS), ± 6 V(CTS-Lab, XL) 


  • Current range : 5 A / 300 mA / 15 mA/ 1 mA (CTS, XL)                              

                                                3 A / 250 mA / 15 mA / 1 mA (Lab)  


  • Channels per unit : 32 ch. max.  (XL ; 20ch.)  


  • Automatic and dynamic current range selection  


  • Continuous current range switching without current interruption  


  • Parallel Operation : Up to 4 channels   


TECHNICAL SPECIFICATIONS



CTS Standard
CTS LAB
CTS LAB XL
Channels per unit (max.)
32
20
Voltage range
0-6V
+/-6V
4-wire measurement
yes 
Min. discharge voltage
200mV or 0.2Ω*current (whichever is greater)
-6V
Current ranges (charge + discharge)
5A/300mA/ 15mA/1mA
3A/250mA/ 15mA/ 1mA
5A/300mA/ 15mA/1mA
Current accuracy
1mA/50µA/ 2.5µA/0.2µA
1mA/50µA/ 2.5µA/0.2µA
1mA/50µA/ 2.5µA/0.2µA
Voltage accuracy
1mV
Resolution
16Bit / 1us 
Parallel operation

Yes, up to 4 channels 
Add. inputs per channel
NTC temperature (for Epcos B57861S0502) optional reference voltage   (+/-6V, 1mV accuracy, leackage < 50nA, 200ms samplerate) 
Digital-IO
Optional, TTL-like, 3 per channel, not isolated
Sampling rate Output change rate
Peak 0.5ms   Min. 10ms (but not more than 1kHz continually per system)
Current rise time
< 50µs
3-Electrode configurations
limited
yes
yes
Control mode
Current, voltage, power, resistance and combinations 
Other methods
Cyclic voltammetry, GITT, …
Software
BaSyTest
Interface
Ethernet
Battery connectors
D-SUB 9-pin   Holders for cylindric cells available 
Size per unit (max.)
19” system 6HE units, 450*280*550mm
Weight per unit (max.)
28kg (32 channels)
Noise
< 55dB(A)
Input power / voltage range
< 1700W   /    110-264VAC / 47-63Hz 
Max. input current per unit
< 16A @ 110V, < 8A @ 220V