BluQCM
특허받은 기술을 보유한 BioLogic 사의 단일 채널 QCM
Maker
BioLogic (France)
Features
• 전기도금/부식, 고체/액체 계면 상호작용 등의 연구를 위한 단일 채널 QCM
• 최대 7개의 overtone 동시 측정 가능
• 특허받은 Quick-lock 구조의 셀: 설정이 용이하며 실험의 재현성을 높임
• 온도 및 흐름 조절 가능(옵션)
Specifications
QSD-300 : Quartz Crystal Microbalnce | |
Operation modes | Tracking and high resolution at single and multiple overtones |
Sensors technologies | QCM (14 mm or 1 inch), HFF-QCM, Love SAW |
Liquid volume above sensor | 3 - 25μl (depending on sensor and cell type) |
Temperature control | Optional (QSD-TCU) |
Measurement in air | YES |
Simultaneous overtones measurements | Up to 7 (Up to 13th) |
Dimensions (H x W x D) | 90 x 220 x 260 (mm) |
Weight | 3 kg |
Sensor | |
Frequency range / MHz | 4 - 160 |
Best frequency resolution / Hz | 0.1 |
Best frequency accuracy / Hz | ± 0.5 |
Max. acquisition rate / points / s | 250 |
Best mass sensitivity in liquid / pg / cm² | 50 |
Best dissipation sensitivity | 10-7 |
FCU : Flow Control Unit | |
Syringe volume / μl | 250 (default) |
Flow rate range for a 250 μl syringe / μl / min | 12.5 - 14500 (standard) 0.625 - 1062.5 (smooth) |
Dimensions (H x W x D) | 195 x 70 x 250 (mm) |
Weight | 0.75 kg |
TCU : Temperature Control Unit | |
Temperature control range | 15 - 45 ℃ |
Temperature stability | ± 0.05 ℃ |
Dimensions (H x W x D) | 60 x 220 x 260 (mm) |
Weight | 4.5 kg |
Cells
EQCM Cells
※전극은 별도로 구매하셔야 합니다.
※Flow EQCM cells : Pt plate counter electrode is integrated in the lid of the cell.
Description | Compatible sensor | Cat. No. |
In-batch EQCM | 14 mm sensor | AW-BEQ01Q |
Air-tight type | AW-BEQATQ | |
1 inch sensor | AW-BEQ02Q | |
Flow EQCM | 14 mm sensor | AW-FEQ01Q |
Hermetic Li research in batch | AW-BEQLIQ |
In-batch EQCM Options
* Aqueous reference electrode (A-012167)
* Non-Aqueous reference electrode (A-013848)
* Counter electrode (A-002234)
Flow EQCM Options
* Aqueous reference electrode (A-012168)
* Non-Aqueous reference electrode (A-013849)
QCM Cells
Description | Compatible sensor | Cat. No. |
In-batch QCM | 14 mm sensor | AW-BQ01Q |
1 inch sensor | AW-BQ02Q | |
HFF sensor | AW-BQ01HQ | |
Flow QCM | 14 mm sensor | AW-FQ01Q |
HFF sensor | AW-FQ01HQ | |
In-batch probe | 14 mm sensor | AW-PEQ11Q |
Sensors
Quartz Crystal Microbalance
FEATURES
• 전기도금/부식, 고체/액체 계면 상호작용 등의 연구를 위한 단일 채널 QCM
• 최대 7개의 overtone 동시 측정 가능
• 특허받은 Quick-lock 구조의 셀: 설정이 용이하며 실험의 재현성을 높임.
• 온도 및 흐름 조절 가능(옵션)
APPLICATIONS
• Electrochemically-driven mass-weighing : electroplating / corrosion, electrode modifications
• Study of solid/liquid interfaces : interface rheology, biomolecular interactions
SPECIFICATIONS
QSD-300 : Quartz Crystal Microbalnce | |
Operation modes | Tracking and high resolution at single and multiple overtones |
Sensors technologies | QCM (14 mm or 1 inch), HFF-QCM, Love SAW |
Liquid volume above sensor | 3 - 25 μl (depending on sensor and cell type) |
Temperature control | Optional (QSD-TCU) |
Measurement in air | YES |
Simultaneous overtones measurements | Up to 7 (Up to 13th) |
Dimensions (H x W x D) / mm | 90 x 220 x 260 |
Weight / kg | 3 |
Sensor | |
Frequency range / MHz | 4 - 160 |
Best frequency resolution / Hz | 0.1 |
Best frequency accuracy / Hz | ± 0.5 |
Max. acquisition rate / points / s | 250 |
Best mass sensitivity in liquid / pg / cm² | 50 |
Best dissipation sensitivity | 10-7 |
FCU : Flow Control Unit | |
Syringe volume / μl | 250 (default) |
Flow rate range for a 250 μl syringe / μl / min | 12.5 - 14500 (standard) 0.625 - 1062.5 (smooth) |
Dimensions (H x W x D) / mm | 195 x 70 x 250 |
Weight / kg | 0.75 |
TCU : Temperature Control Unit | |
Temperature control range / ℃ | 15 - 45 |
Temperature stability / ℃ | ± 0.05 |
Dimensions (H x W x D) / mm | 60 x 220 x 260 |
Weight / kg | 4.5 |
Cells
In-batch EQCM
Flow EQCM
Hermetic Li research
in batch EQCM
In-batch QCM
Flow QCM
In-batch probe QCM
EQCM Cells
Description | Compatible sensor | Cat. No. | Options | ||
Aqueous reference electrode | Non-Aqueous reference electrode | Counter electrode | |||
In-batch EQCM | 14 mm sensor | AW-BEQ01Q | A-012167 | A-013848 | A-002234 |
Air-tight type | AW-BEQATQ | ||||
1 inch sensor | AW-BEQ02Q | ||||
Flow EQCM | 14 mm sensor | AW-FEQ01Q | A-012168 | A-013849 | - |
Hermetic Li research in batch | AW-BEQLIQ | - |
※ 전극은 별도로 구매하셔야 합니다.
※ Flow EQCM cells : Pt plate counter electrode is integrated in the lid of the cell.
QCM Cells
Description | Compatible sensor | Cat. No. |
In-batch QCM | 14 mm sensor | AW-BQ01Q |
1 inch sensor | AW-BQ02Q | |
HFF sensor | AW-BQ01HQ | |
Flow QCM | 14 mm sensor | AW-FQ01Q |
HFF sensor | AW-FQ01HQ | |
In-batch probe | 14 mm sensor | AW-PEQ11Q |
Sensors
Type | Substrate | Material | Resonant frequency / MHz | Finish | Qty. | Cat. No. |
14 mm WRAPPED | Ti | Au | 5 | Polished | 10 | AW-R5AU11P |
Ti | Au | 5 | Rough | 10 | AW-R5AU11 | |
Cr | Au | 5 | Polished | 10 | AW-R5AU10P | |
Cr | SiO2 over Au | 5 | Polished | 10 | AW-R5SIO2P | |
- | Al | 5 | Polished | 10 | AW-R5ALP | |
- | Cu | 5 | Polished | 10 | AW-R5CUP | |
- | Fe | 5 | Polished | 10 | AW-R5FEP | |
Ti | Au | 10 | Rough | 10 | AW-R10AU11 | |
Ti | Au | 10 | Polished | 10 | AW-R10AU11P | |
- | Pt | 10 | Polished | 10 | AW-R10PT10P | |
- | C | 10 | Polished | 10 | AW-R10C10P | |
Cr | Au | 10 | Polished | 10 | AW-R10AU10P | |
1 inch | Ti | Au | 5 | Polished | 5 | AW-R5AU21P |
Cr | Au | 5 | Polished | 5 | AW-R5AU20P | |
- | Pt | 5 | Polished | 5 | AW-R5PT20P | |
Ti | Au | 9 | Polished | 5 | AW-R9AU21P | |
Ti | Au | 9 | Rough | 5 | AW-R9AU21 | |
Cr | Au | 9 | Rough | 5 | AW-R9AU20 | |
Cr | Au | 9 | Polished | 5 | AW-R9AU20P | |
HFF-QCM | Cr | Au | 50 | - | 5 | AW-R50AU01H |
Cr | Au | 100 | - | 5 | AW-R100AU01H | |
Cr | Au | 150 | - | 5 | AW-R150AU01H |