Specifications | |
Mains voltage | 208/380/400/480/500/660 V (3~, PE) 230/400 V (1~, PE) ±10% without N, 16, 17A, 50 Hz or 60 Hz |
Output voltage | 10 – 600 V ±1% permanent or adjustable (other ranges on request) |
Output frequency | 45-105 Hz, 195-805 Hz, 95-420 Hz (other ranges on request) |
Output frequency accuracy | ±0.1% fs |
Rated output power | 10 – 500 kVA |
Voltage regulation | Static: ±1% fs Dynamic: ±4% at 100% load change (50/60 Hz), ±8% (400/800 Hz) Asymmetric load: ±2% at 100% unbalance load |
Regulation time effective value | < 25 msec |
Regulation time momentary value | < 4 msec |
Overload characteristic | 150% for 1 min. / 125% for 10 min. / 110% for 20 min. |
Short-circuit characteristic | 2 × I_nom. at 1-phase output 2.4 × I_nom. at 3-phase output for 5s according to EN 62040-1 |
Waveform | Sinusoidal |
Distortion factor (with linear load) | ≤ 3% (100 Hz ≤ 5%) |
Applied Guidelines and Standards | |
Low voltage directive | 2014/35/EU |
EMC-Guideline | 2014/30/EU |
RoHS-Guideline | 2011/65/EU |
EMC | EN 62040-2 requirements for EMC (UPS) EN 61000-6-2 noise immunity EN 61000-6-4 transient emissions |
Permissible power factor | Power derating, if power factor deviates from 0.8 lagging |
Crest factor of the load current | ≤ 2.3 (at 100% Load) |
Standard Design | |
Permissible ambient temperature | +5 up to +40°C |
Environmental conditions | Storage: EN 60721-3-1: IK21 / 1M11 Transport: EN 60721-3-2: K12 / 2M4 (-45 up to +70°C) Operation: EN 60721-3-3: 3K2 / 3M11 (+5 up to +40°C, ≤85% relative humidity, no condensation) Degree of pollution 2 |
Permissible operating altitude | 1000 m above m.s.l with rated load |
Protection class | IP 20 according to IEC 60529 |
Paint finish | RAL 7035 |
Cooling | "AN" natural air cooling "AF" forced air cooling "AFR" air-cooled and recooling |
Electrode Testing Solution
Electrode Integrated Testing Instrument
Maker
IEST (China)
Features
• Electrode Resistance Analyzer
• Online Electrode Resistance Analyzer
• Rolling Type Electrode Resistance Analyzer
• Electrode Integrated Testing Instrument
• Electrolyte Wetting Testing System
• Glove Box Type Electrode Resistance Analyzer
Applications
• Active material conductivity evaluation
• Conductivity evaluation of conductor types
• Evaluation of electrode primer technology
• Conductive agent distribution uniformity evaluation
• Uniformity evaluation of silicon-carbon hybrid material
• Analysis of electrode resistance during high temperature cycle & storage
Specifications
Model | BER2100 | BER2200 |
Press mode | Cylinder Pipeline gas required,range:5-35MPa) | |
Testable parameter | Resistance, Pressure Temperature and humidity | Resistance, Pressure Temperature and humidity conductivity, resistivity |
Function | One point test Constant pressure condition | Included BER2100 function Automatic measurement software |
Model | BER2300 | BER2500 |
Press mode | Servo motor (No pipeline gas required, range:5-60MPa) | |
Testable parameter | Resistance, Pressure Temperature and humidity conductivity, resistivity | Resistance, Pressure Temperature humidity, conductivity, resistivity, thickness, compaction density |
Function | Included BER2100 function Variable pressure | Included BER2300 function Thickness mesurement Compaction density measurement |